REAL-TIME PCR

Automated qPCR setup, from sample preparation through to thermal cycling

OVERVIEW
Myra automates qPCR reaction setup across research, genomics, and applied laboratory workflows.

The liquid handler takes care of master mix preparation, sample dispensing, standard curve construction, and reaction plate completion with sub-microliter precision. Setup is instrument-agnostic by design, with native integration for the BMS Mic cycler and Workbench export to all major third-party platforms.

APPLICATIONS

Where automated qPCR setup makes a measurable difference

Manual pipetting introduces specific failure modes into qPCR setup, and small volume errors have outsized consequences: imprecise master mix dispensing that shifts Cq values by fractions of a cycle, inconsistent sample volumes that introduce inter-well variability that confounds relative quantification analysis, or standard curve dilution errors that undermine absolute quantification across an entire run.

NGS library quantification

Adapter-specific library quantification using the NEB NGS Library Quantification Kit. Workbench exports plate layout with sample names and standard concentrations directly to your qPCR instrument. This is the foundation of accurate molar normalization before multiplexed sequencing.

Gene expression analysis

Relative quantification of target genes across treatment groups using reference gene normalization. Consistent master mix dispensing and sample transfer accuracy are the primary determinants of Cq reproducibility across replicates and plates in multi-assay gene expression studies.

Pathogen detection and diagnostics

High-throughput qPCR setup for infectious disease detection, including integrated sample preparation from VTM and oropharyngeal swabs prior to reaction setup. Myra’s swab-aware liquid handling and MyraVision® deck verification are directly relevant to diagnostic workflows that depend on sample integrity and operator consistency.

Environmental and food safety testing

Pathogen and GMO screening workflows requiring consistent multi-assay plate setup across large sample batches. Automated standard curve preparation and replicate dispensing reduce the inter-run variability that compromises detection limit performance in quantitative environmental monitoring assays.

Veterinary diagnostics

Animal health diagnostics requiring reproducible reaction setup across diverse sample types and assay targets. Myra’s configurable sample preparation options accommodate variable input volumes and tube formats encountered in veterinary sample panels.

Biotech quality control

qPCR-based quality control for biologics manufacturing, including mycoplasma testing, residual DNA quantification, and identity testing. LIMS integration via Workbench supports traceability requirements in GMP-adjacent workflows.

WORKFLOW

How Myra handles qPCR setup end to end

Workbench populates reactions based on sample inputs and assay definitions. Sources, reaction plates, and tubes are allocated to the deck automatically, requiring only manual addition of reagent components before the run starts. MyraVision verifies the deck layout before execution begins.

Step 1. Sample preparation (optional)

Integrated sample preparation prior to reaction setup supports QIAGEN’s QIAprep& Viral RNA UM Kit for VTM samples, configurable Custom Simple Prep for liquid-based preparation workflows, and Independent Prep using Python-based MyraScript for advanced workflows including magnetic bead-based extraction. Swab-aware aspiration handles Rhinoswab and Flocked swab types with collision avoidance — aspirating from the centre or side of the tube to avoid the swab body.

Step 2. Assay and sample configuration

Assays define all components, chemistry, run profiles, and reaction setup parameters. Multiple assays can be linked to a single run, with reactions grouped by sample, assay, panel, or qPCR profile. Sample annotations, group assignments, and replicate counts are configured in Workbench — CSV import supported for large sample batches.

Step 3. Standard curve preparation

Serial dilution and standard curve construction automated on-deck in three modes: Constructed Series (single dilution factor), Constructed Custom (user-defined concentrations per standard), or Pre-prepared (known concentrations entered directly). Diluent is auto-filled from the assay definition; replicate counts and standard concentrations are configurable per run.

Step 4. Reaction plate setup

Master mix and sample dispensing into the reaction plate. Fill Type options include Linear, Checkerboard (for positive-negative patterns), Matched Source Position, Random, and Multi-Channel — the Multi-Channel fill type determines optimum reaction placements for 4-channel pipette head use, available from Workbench 2.4. Edge effect mitigation via configurable exclusion of outer wells. Controls placement before or after each reaction group, configurable per assay.

Step 5. Thermal cycling

Completed reaction plate transferred to the qPCR cycler of choice. On the Myra+, Workbench can automatically trigger cycler runs upon completion of setup — enabling a fully integrated workflow from reaction preparation through to thermal cycling without manual plate transfer.
Master mix and sample are dispensed into the reaction plate. Fill Type options include Linear, Checkerboard (for positive-negative patterns), Matched Source Position, Random, and Multi-Channel. The Multi-Channel fill type determines optimum reaction placements for 4-channel pipette head use, available from Workbench 2.4. Edge effect mitigation via configurable exclusion of outer wells. Controls placement before or after each reaction group, configurable per assay.
CYCLER COMPATIBILITY

Instrument-agnostic setup with native Mic integration

Myra’s qPCR setup workflow is platform-agnostic at the liquid handling level. For labs running the BMS Mic cycler, Workbench provides direct integration, with both instruments operated from a single interface and no export required. For all other platforms, Workbench generates instrument-specific import files that carry sample names, target information, and standard concentrations directly into the cycler software.

NATIVE INTEGRATION

BMS Mic qPCR Cycler

Myra and Mic operated from a single Workbench interface. No export or import required; sample names transfer directly. Multiple Mic cyclers can be configured from a single Myra run, and their results are combined in a unified project file for comparative analysis across runs.

NATIVE INTEGRATION

BMS Myra+ Cycler

Integrated thermal cycling triggered automatically upon run completion. Reaction preparation and thermal cycling run as one fully enclosed workflow, with no manual plate transfer and both steps completed within Workbench.

WORKBENCH EXPORT

Thermo Fisher QuantStudio

Plate layout exported in QuantStudio format compatible with software v1.5 and v2.6, including sample type, target information, and standard concentrations.

WORKBENCH EXPORT

Bio-Rad CFX

Export in CFX Maestro spreadsheet import format or CFX LIMS import file format, including sample type, target information, and standard concentrations.

WORKBENCH EXPORT

Qiagen Rotor-Gene Q

SMP format export for Rotor-Gene Q, including sample arrangement by page. 384-well Qiagen system export validated at the Ramaciotti Centre for Genomics, UNSW Sydney, for NGS library quantification workflows.

WORKBENCH EXPORT

Additional platforms

Workbench supports export to all major qPCR platforms via CSV. Contact BMS to confirm export format availability for specific cycler models not listed here.

MYRAINTELLIGENCE®

AI-driven verification and adaptive handling across the qPCR workflow

MyraIntelligence® is the machine-learning-enabled intelligence layer that runs across Myra’s automated liquid handling platform. It combines simulation, computer vision, and real-time pressure sensing into a closed-loop system that checks the run before and during execution. In qPCR setup, all three components contribute directly to run reliability.

INTELLIGENT RUN PLANNING

MyraSim®

Dynamically calculates optimal volumes required to complete the run without failure, analyzes every operation before execution to flag potential issues, and provides optimization suggestions. For qPCR setup, this means volume sufficiency for master mix, standard curve dilutions, and sample transfers is verified before the run starts, so reagent doesn’t run out mid-run.

DECK VERIFICATION BEFORE EVERY RUN

MyraVision®

Computer vision scanning confirms consumable type, detects missing plasticware, and verifies cap removal across the full deck layout before execution begins. In qPCR setup, where an uncapped reagent tube or incorrectly positioned reaction plate can invalidate an entire run, pre-run visual verification adds a quality check that doesn’t rely on the operator catching every error.

ADAPTIVE PIPETTING DURING EXECUTION

MyraSense®

Pressure-based liquid level sensing at every aspiration step, with real-time optimization of mix type based on liquid level and tube type. Because qPCR master mix can be viscous and sensitive to over-mixing, MyraSense adapts dispensing behavior to the actual liquid properties rather than applying fixed parameters, reducing both under-mixing and reagent degradation from excessive agitation.

VALIDATED SCRIPTS

Real-Time PCR scripts for Myra

Scripts are validated by BMS or developed in partnership with kit manufacturers and the Myra user community. The extraction script library is actively growing, and additional sample types and extraction chemistries are in development.

CASE STUDIES

Performance across research, genomics, and applied laboratory settings

BMS APPLICATION DEVELOPMENT

Gene expression — relative quantification

Myra + Mic, anabolic steroid gene expression study

Relative quantification study investigating the effects of oxymetholone, testosterone, and nandrolone on expression of ACE, ACTN3, and Calcineurin target genes, with B2M and GAPDH as reference genes. 16 samples across four treatment groups, assembled and run on Myra with amplification on the Mic qPCR Cycler. REST method used for non-parametric error calculation. The study validates Myra’s ability to execute multi-assay, multi-group relative quantification workflows with sufficient precision to detect biologically meaningful expression differences.

RESULTS

REST Analysis of data set

Testosterone and nandrolone significantly increased the expression of all three target genes (ACE, ACTN3, Calcineurin), with testosterone showing a more than 25-fold increase in ACE expression. In contrast, oxymetholone selectively reduced the expression of Calcineurin by half but did not affect ACE or ACTN3.

Frequently Asked Questions

Which qPCR cyclers is Myra compatible with?

Myra is instrument-agnostic. The BMS Mic qPCR Cycler and Myra+ have native integration through Workbench, so experiment data does not need to be exported and re-imported between the instruments.

For third-party platforms, Workbench generates instrument-specific import files for QuantStudio, Bio-Rad CFX Maestro, and Qiagen Rotor-Gene Q. Other platforms are supported through CSV export.

What does automated qPCR setup include?

The automated qPCR setup on Myra includes master mix preparation, sample dispensing, serial dilution for standard curve construction, and reaction plate completion. Sample preparation from raw sample types can also be included as an upstream step.

Thermal cycling takes place off-deck or on the integrated Mic qPCR cycler with Myra+. Workbench uses sample inputs and assay definitions to populate the reactions before the run.

How does automated setup improve qPCR reproducibility?

Automated setup reduces variability introduced during repetitive manual pipetting. Consistent master mix and sample dispensing limits inter-well variation, while automated serial dilution lowers the risk of errors during standard curve preparation.

Can Myra be used for NGS library quantification?

Yes. Myra sets up adapter-specific library quantification reactions using the NEB NGS Library Quantification Kit. Workbench exports the plate layout with sample names and standard concentrations to the qPCR instrument.

The resulting concentration data supports molar normalization before equimolar pooling for multiplexed sequencing. The Ramaciotti Centre for Genomics at UNSW Sydney uses Myra for NGS library normalization and pooling, including the preparation of 24-plex libraries normalized to 2 nM for sequencing on the Illumina NovaSeq X Plus.

Automate your qPCR setup on Myra