SPRI BEAD CLEANUP

Automated SPRI bead cleanup and size selection

OVERVIEW

Solid Phase Reversible Immobilization bead cleanup is the step that sits between the enzymatic reaction and the next analytical stage in a molecular workflow.

The bead-to-sample ratio is the variable that controls fragment size selection, and its precision is what separates a clean, tight Bioanalyzer trace from one that requires repeat preparation.

THE CHALLENGE

Why bead ratio consistency is harder to achieve than it appears

SPRI bead cleanup follows a simple sequence. The bead ratio controls which fragments bind, then ethanol washes remove contaminants before elution releases the purified DNA. The bead-to-sample ratio is a volumetric relationship that is extremely sensitive to pipetting precision, particularly at the lower volumes used for single-sided cleanup and at the tighter ratios used for double-sided size selection.

A 5% error in a 50 µL bead transfer represents a deviation of just 2.5 µL, yet even small variations in bead-to-sample ratios can shift size-selection cut-offs and affect fragment size consistency between samples. When 24 samples are prepared by hand, uneven bead volumes across the plate are the primary source of sample-to-sample variability, leading to inconsistent fragment size profiles on the Bioanalyzer or Qsep.

Double-sided size selection compounds the error, because the left-side and right-side bead ratios must each be consistent. The effect on size cutoff accuracy is largest in NGS applications, where a tight insert size distribution is critical for sequencing efficiency.

Bead loss is the same risk here as it is in nucleic acid extraction. During supernatant removal after magnetic capture, a pipette tip that seals against the well base creates negative pressure. When the seal releases, the resulting suction can pull beads from the pellet.

Myra’s Dynamic Retract detects tip sealing and retracts incrementally before this pressure builds. This prevents bead loss at every wash and supernatant removal step, whether the cleanup runs on its own or as part of a library preparation workflow.

APPLICATIONS

Where SPRI bead cleanup sits in molecular workflows

SPRI bead cleanup appears at several points across NGS, PCR, cloning, and diagnostic workflows.

NGS library preparation

Cleanup occurs after tagmentation, ligation, and PCR within library prep protocols. The uniformity of the fragment size distribution after bead cleanup directly affects cluster density and read quality, as well as the insert size profile in the final data. Myra runs all cleanup steps within a library prep run without a plate handoff.

PCR product purification

Removes excess primers, nucleotides, salts, and polymerase from PCR amplicons before sequencing, cloning, restriction digestion, or quantification. Single-sided cleanup at standard bead ratios suit amplicons above 100 bp, while size selection isolates specific fragment populations from complex PCR reactions.

Fragment size selection

Double-sided size selection narrows fragment size distributions before sequencing, particularly in PCR-free library preparation, where insert size depends entirely on bead cleanup rather than amplification. Left-side and right-side bead ratios independently define the lower and upper size cutoffs.

CRISPR-Cas9 workflows

Cleanup of donor DNA templates, purification of edited fragments before sequencing or analysis, and size selection of CRISPR components. Consistent cleanup at the editing verification step ensures that downstream sequencing data reliably distinguishes on-target and off-target events.

Fragment analysis

Preparation of size-selected fragment populations for capillary electrophoresis fragment analysis, microsatellite genotyping, and STR profiling. Consistent bead ratios determine peak resolution and prevent neighboring fragment classes from overlapping in the electropherogram.

Diagnostic sample preparation

Enrichment for target DNA or RNA fragments of specific sizes to improve the sensitivity and specificity of downstream diagnostic assays. Batch-to-batch variability in cleanup performance can affect assay performance thresholds, which makes consistent automated cleanup especially relevant in diagnostics.

CLEANUP MODES

Single-sided cleanup, double-sided size selection, and generic SPRI

The Myra liquid handling system supports all three principal SPRI workflow configurations. Bead volumes, ethanol wash volumes, air-dry timing, and elution volumes are all set through script parameters, so no modification is required for routine changes.

SINGLE-SIDED

Left-side cleanup

Standard PCR product and library cleanup using a single bead ratio to remove fragments below the size cutoff. This cleanup step removes primers, primer dimers, adapter dimers, and small DNA fragments while retaining the target library or amplicon population. Bead-to-sample ratios of 0.6× to 1.8× are validated for input volumes up to 140 µL.

DOUBLE-SIDED

Size selection

Two sequential bead ratios define the lower and upper fragment size cutoffs. The right-side bead addition comes first to remove large fragments, followed by the left-side to capture the target population. Double-sided size selection is critical for PCR-free library preparation and any application requiring a narrow insert size distribution. Both bead volumes can be configured independently.

GENERIC

Custom SPRI protocols

Myra’s configurable SPRI script supports custom bead chemistries and non-standard protocols. Incubation times, wash steps, air-dry duration, and elution volumes are all configurable. Compatible with any paramagnetic bead-based cleanup chemistry that follows the standard bind-wash-elute format.

WORKFLOW

How Myra executes SPRI bead cleanup

The automated cleanup workflow follows the same structure for single-sided and double-sided configurations, with the double-sided protocol adding a right-side bead step before the left-side capture. All steps run on deck using the 96-well magnetic station.

Step 1. Bead addition and incubation

Bead suspension dispensed at the configured ratio to the sample plate. Consistent bead-to-sample ratios across all wells — the primary variable controlling size cutoff. For double-sided selection, right-side beads are added first at the lower ratio to remove large fragments before the target-capturing left-side addition. Intelligent mixing ensures complete bead resuspension and homogeneous binding contact before magnetic capture.

Step 2. Magnetic capture and supernatant removal

96-well magnetic station engages to capture beads. Supernatant removed to very low residual volumes — MyraSense pressure sensing detects liquid below dead volume without relying on programmed height offsets. Dynamic Retract protects against tip sealing during aspiration, preventing the fluidic suction event that would pull beads from the pellet and reduce yield.

Step 3. Ethanol wash steps

Two sequential 80% ethanol washes with full coverage of the bead pellet. Non-contact dispensing protects pellet integrity during wash buffer addition. Complete wash removal confirmed by MyraSense before proceeding — residual ethanol in the final eluate inhibits downstream polymerase activity and distorts spectrophotometric concentration measurements.

Step 4. Air-dry

Scripted air-dry period — consistent timing across all wells. Over-drying increases bead aggregation and reduces DNA recovery from the pellet during elution; under-drying leaves residual ethanol that co-purifies into the eluate. The scripted timer removes the judgment call that introduces inter-well variability in manual cleanup.

Step 5. Elution

Elution buffer dispensed onto dried beads; magnets released. Bead resuspension at configured mixing speed and duration. Magnetic recapture followed by eluate transfer to a clean output plate. Dynamic Retract active throughout — at elution volumes, tip sealing against the well base is most likely and the consequences for recovery most direct.
KEY CAPABILITIES

What makes Myra suited to SPRI bead cleanup

Pressure-based liquid level sensing

MyraSense™ detects liquid below the dead volume of wells, which maximizes supernatant and wash removal. It does not rely on fixed-height aspiration, which may not reach actual liquid levels in partially filled wells.

96-well magnetic station

Integrated, automated magnet control keeps bead capture timing consistent across all samples in a run. Magnets are applied to groups of wells at defined intervals, which eliminates the variable capture timing that manual handling introduces across a plate.

Non-contact dispensing

Wash buffer is dispensed without tip contact with the destination surface. This protects pellet integrity during wash addition and reduces carryover risk between wells.

User-configurable parameters

Bead volume, ethanol volume, incubation times, air-dry duration, and elution volume are all set through parameters at the top of the script, so no editing is required to adapt the protocol to different bead ratios or sample volumes.

Intelligent mixing

Vortex, advanced, and simple mixing strategies are selected by volume and labware so the beads are fully resuspended before binding. Settled beads reduce the available surface area for DNA capture and shift the effective bead ratio, directly affecting size cutoff performance.

Dynamic Retract

Detects tip sealing against the well base during aspiration and retracts incrementally before negative pressure builds. This prevents bead loss from fluidic suction events during supernatant removal and elution transfer, protecting yield at every aspiration step over the pellet.

VALIDATED KITS

SPRI bead cleanup scripts for Myra

Scripts are validated by BMS, in partnership with kit manufacturers, or by the Myra user community. All kits follow the standard SPRI bind-wash-elute chemistry and are configurable within the same script framework.

CASE STUDY — THIRD PARTY

Higher PCR product yield and tighter CV than manual preparation using CleanNGS beads

Labgene Scientific SA, Switzerland. Validated partner evaluation using CleanNGS beads on Myra.

SETUP

Automated vs manual cleanup of PCR products across 16 samples

Labgene Scientific SA, a Swiss life science distributor and BMS partner, conducted a direct comparison between automated SPRI bead cleanup on Myra and manual preparation using CleanNGS beads (CleanNA). Sixteen PCR product samples were processed in parallel using both methods. Fragment size and size distribution were assessed by capillary electrophoresis using a BiOptic Qsep1-Plus fragment analyzer. The yield of purified PCR product was measured across all replicates to compare the mean yield and inter-sample consistency between the two preparation methods.

RESULTS

Significantly higher yield and improved consistency across all replicates

Automated SPRI bead cleanup on Myra produced significantly higher yields of purified PCR product than the manual method across all 16 samples. Replicate CV was also tighter for Myra-prepared samples than for the manual method, reflecting the consistency of automated bead ratio dispensing. Fragment size analysis by CE confirmed correct fragment sizes across all samples prepared by both methods, showing that automated cleanup on Myra preserved fragment integrity while improving yield and consistency.

Higher

PCR product yield vs manual method across all 16 samples

Tighter

CV across replicates compared to manual preparation

16/16

Correct fragment sizes by CE across all Myra-prepared samples

DNA yield using Myra vs. manual with CleanNGS beads.

The yield improvement is consistent with the bead ratio precision described above. Manual bead dispensing introduces well-to-well volume variability that shifts the effective bead-to-sample ratio, reducing the proportion of target fragments captured from each sample. Automated dispensing with consistent bead volumes across all wells maximizes capture efficiency while holding the size cutoff stable across the plate.

WORKFLOW INTEGRATION

Bead cleanup in the context of the broader Myra workflow

SPRI bead cleanup on Myra connects directly to the upstream and downstream steps that surround it. It can run as a standalone cleanup or as an integrated step within a larger workflow on the same automated liquid handling platform.

qPCR setup

Eluates loaded directly as sample inputs. Reaction plates exported to Mic, QuantStudio, CFX, or Rotor-Gene Q.

NGS library preparation

Extracted gDNA or total RNA used as input for library prep across Illumina, ONT, and PacBio platforms.

Normalization and pooling

Post-quantification molar normalization, equimolar pooling, and Illumina loading preparation on the same platform.

Nucleic acid extraction

Post-extraction cleanup of eluates is performed before library prep or direct amplification.

Frequently Asked Questions

What bead-to-sample ratios can Myra run?

Bead-to-sample ratios of 0.6× to 1.8× are validated for single-sided cleanup at input volumes up to 140 µL. For double-sided size selection, the right-side and left-side bead volumes are configured independently.

Can Myra do double-sided size selection, not just cleanup?

Yes. The double-sided capability adds a right-side bead addition to remove large fragments before the left-side addition captures the target population. Both bead volumes are configured independently, so the lower and upper size cutoffs are set separately. This is critical for PCR-free library preparation, where insert size depends entirely on bead cleanup rather than amplification.

Do I have to edit the script to change bead volume or elution volume?

No. Bead volume, ethanol wash volume, incubation times, air-dry duration, and elution volume are user-configurable parameters at the top of the script, so routine changes require no editing.

How does Myra prevent bead loss during supernatant removal?

A tip that seals against the well base builds negative pressure, and when the seal releases, the suction can pull beads off the pellet. Dynamic Retract detects tip sealing during aspiration and retracts incrementally before that pressure builds. MyraSense pressure-based liquid level sensing also detects liquid below the dead volume of the well, so supernatant and ethanol removal do not rely on fixed-height aspiration.

Automate your SPRI bead cleanup on Myra