No risk, no obligation
14-day trial
FROM
£9,950
MIC 2 CHANNEL
The most robust qPCR system on the market.
Ultimate thermal and optical uniformity between all samples.
No variation from instrument to instrument.
35 cycles in 25 minutes delivers precision and productivity
Zero edge effect with best-in-class uniformity down to +- 0.05 degrees C
Small, light, go-anywhere. Identical results in lab and field
For heavy-duty use. 2-year warranty and no annual maintenance required
Mic qPCR has zero drift, so no calibration is ever needed
The Mic ensure fast, highly accurate results
BMS devices are effortlessly portable and intuitive, helping Cignpost to build a substantial distributed laboratory network to meet our client needs, often in remote locations, across the globe.
Richard Acton - CTO, Cignpost Diagnostics
Discover the features and benefits that make Mic the first choice for healthcare professionals and researchers everywhere.
We guarantee you'll find it user-friendly and packed with intelligent features.
Yes. The protocols for most assays will transfer to Mic without any changes. In some cases where a standard Taq polymerase is used (i.e. not specified to be compatible with fast cycling) we suggest you use the ‘Standard Taq Temperature Control’ option in the run profile. This slows down the heating rate of the Mic instrument to be closer to other instruments.
The Magnetic Induction system used by Mic to heat the sample works on the same principle as an induction cooktop. The benefits over a peltier block based system are:
Yes. The portability and robustness of Mic is a huge advantage for anyone needing to do real time PCR in the field. Mic has proven to run reliably off batteries (car, truck or solar powered) using an inverter to supply between 100V and 240V AC.
Yes. The protocols for most assays will transfer to Mic without any changes. In some cases where a standard Taq polymerase is used (i.e. not specified to be compatible with fast cycling) we suggest you Having flexibility in running different volumes is important to many users. Small volumes allow for significant reductions in reagent costs. Higher volumes allow for greater sensitivity in their test by increasing the chances of detecting the target. Mic maintains the same performance for any volume from 5 to 30μL. the ‘Standard Taq Temperature Control’ option in the run profile. This slows down the heating rate of the Mic instrument to be closer to other instruments.
A thermal sensor is embedded in the spinning rotor which measures tube temperature directly. This sensor does not drift over time so there is no need for it to be recalibrated. For those customers who require an annual validation report, we have a Temperature Verification System.
Mic's optical system has a fixed optical path and no moving parts. This means there is never any need for optical alignment or calibration. Because every sample spins past the same detector there are no reference dyes or crosstalk compensation is required either.